Typically we suggest you have an air gap between 1 2 and 3 4 for the radiant barrier to work.
Gap between roof and wall in attic. There is a gap where the roof meets the wall. The roof hangs over the gap to keep the rain out but birds and bees are coming up through the gap. Gap between roof and wall in attic. The success of a vented attic or roof deck relies on its airtightness.
Attic walls are typically found above full gable walls forming a gable or closing the top portion of a side wall beneath a shed roof. If you suspect that air is leaking up and out of a party wall made of concrete blocks hire a contractor to seal the blocks. 2d extend insulation into joist space to reduce air flows. Is it supposed to be like that.
We bought a new house last year. If you meant an eave gap under an entirely new roof between the top of the wall and the underside of the roof that might well be especially if between the rafters or truss rafter tails your eave ventilation gap which for a ventilated unheated unair conditioned attic provides ventilation air to control heat and moisure buildup. Along the edge of shared walls. Going up to the loft we noticed there is a considerable gap 5 6 cm between the roof and the wall like this.
So you re talking about you re going to reroof and you have a gap between the wall sheathing and the roof sheathing. Building regulation requirements attic conversion insulation between the roof rafters we have had our attic converted into a bedroom and ensuite. And i was advised that that gap should be protected by a home inspector. The shared wall between units in duplexes triplexes and row houses and the edge of the attic floor.
In finished attic rooms with or without dormer insulate 2a between the studs of knee walls 2b between the studs and rafters of exterior walls and roof 2c and ceilings with cold spaces above. But where the wall sheathing meets the roof sheathing there is a gap of approximately 1 8 of an inch. Now wait a minute. When the program detects an open space between a wall and the roof plane above it it automatically creates an attic wall on the floor above that wall to fill in the gap.
Ensure that this gap is well sealed. The space above the top plate of exterior walls at the bottom of each rafter bay is especially important. I was thinking of either putting a screen over the gap or just sealing in but was wondering if it served a purpose ventilation maybe. There is a low wall which has 2 hatches built into the wall.
Air gaps larger than this work well too they promote ventilation on the foil and help keep the air dry and the air temps lower. Baffles placed in this area channel intake air into either the attic space or vent chutes and also prevent insulation from falling into the soffit and blocking airflow.